Liquid cooling in AI data centers explained
Liquid cooling carries heat away from chips with a coolant instead of air. As chips draw more power, data-center heat loads are expected to outgrow air cooling, and NVIDIA's GB200 NVL72 and GB300 NVL72 rack systems are liquid-cooled designs.[1][2] A 2025 life-cycle study by Microsoft and WSP authors found cold plates and immersion cut energy demand by 15-20% and blue water use by 31-52% compared with air cooling.[3]
Liquid cooling moves heat away from processors with a fluid rather than with air blown across heat sinks. It matters now because AI chips draw more power each generation: a 2025 Nature study by Microsoft and WSP authors says that, with Moore’s law and Dennard scaling slowing, better chip performance needs more power and makes more heat, which will probably push data-center heat loads beyond what air cooling can handle.[1] For the wider picture of how these buildings work, see how data centers work.
Why air is running out
Chips turn the power they use into heat, and newer chips use more power, so fans alone struggle to keep up.[1] If chips get too hot they slow down and perform worse, and operators have to spread servers further apart.[4]
The Nature study notes that both power (watts) and heat flux (watts per unit area) have been rising for GPUs and CPUs, and that exceeding thermal limits can raise emissions, cut clock frequency and degrade components; excess heat also reduces server packing density.[1][4] Cooling is a large share of the energy bill: in 2023 the US Department of Energy said cooling can account for up to 40% of a data center’s energy use.[5] Total demand is growing too: a Lawrence Berkeley National Laboratory report released by the DOE found data centers used about 4.4% of US electricity in 2023 and could use 6.7% to 12% by 2028.[6] See AI data centers and power for the grid side.
Direct-to-chip cooling
One approach clamps a metal “cold plate” onto the hottest chips. Liquid flows through tiny channels inside the plate, picks up the heat and carries it out of the server. Some air cooling may still be needed for the rest of the server.[7][8]
Cold plates are small heat-exchange modules with microchannels, placed on high-power chips and high-density components; a coolant loop carries the heat out of the server. The same study gives a cold-plate system’s liquid-to-air heat transfer ratio as 50% to 80% or more, while immersion fluid absorbs all of the heat.[7][9] Cold plates can be deployed in existing air-cooled halls with less disruption, but installation can be complex and some air cooling may still be needed.[8] The Open Compute Project’s cooling work covers the surrounding plumbing as well: cold plates, coolant distribution units, immersion, door heat exchangers and heat reuse.[10]
NVIDIA’s rack-scale AI systems are built around liquid cooling. It describes the GB200 NVL72, which joins 36 Grace CPUs and 72 Blackwell GPUs, as a liquid-cooled design, and the GB300 NVL72 as fully liquid-cooled.[2] NVIDIA says liquid cooling increases compute density and reduces floor space.[11]
Immersion cooling
Immersion cooling goes further: whole servers sit in a tank of special fluid that does not conduct electricity. The fluid soaks up all the heat, so the servers need no fans.[9]
In one-phase immersion, heat moves into the fluid by natural or forced convection and pumps push the fluid through the servers; the fluids are usually hydrocarbon-based. In two-phase immersion, the fluid boils at 30 to 50 °C, rises as vapour to a condenser coil and condenses back to liquid.[12] One-phase systems use cheaper coolants and simpler tanks but perform less well at the chip level. Two-phase tanks can handle more than 500 kW, but their fluids are PFAS, which have been under legislative scrutiny.[8] The DOE’s COOLERCHIPS programme funded work in this area, including an award to Intel Federal to adapt a two-phase immersion system.[13]
Energy, water and the evidence
A 2025 life-cycle assessment by Microsoft and WSP authors, which they describe as the first public one of its kind by a hyperscale cloud provider, found that cold plates and immersion cooling cut greenhouse gas emissions by 15-21%, energy demand by 15-20% and blue water consumption by 31-52% compared with air cooling.[3] These figures come from one company’s own analysis, and results at other sites may differ.
Public research money is going into the problem. In May 2023 the DOE announced $40 million for 15 COOLERCHIPS projects aimed at more efficient data-center cooling.[5] Supercomputers are not new to this: the Open Compute Project notes that high-performance computing has long used liquid cooling.[10] Europe’s JUPITER system is warm-water cooled, and its operator plans to feed the waste heat into the campus heating network.[14]
This page explains cooling methods; it does not compare vendors or recommend products. For the energy demand of AI data centers over time, read the AI data-center power tracker.
Read next
Next in the crash course
How supercomputers work: exascale and the TOP500
How supercomputers split one problem across millions of cores, what exascale means, how the TOP500 ranks machines and which systems lead the November 2026 list.
Questions readers ask
Why do AI data centers need liquid cooling?
Chip power and heat flux keep rising as Moore's law and Dennard scaling slow, and a 2025 Nature study expects data-center heat loads to outgrow current air cooling. Excess heat also slows chips and limits how densely servers can be packed.[1][4]
What is the difference between direct-to-chip and immersion cooling?
Direct-to-chip cooling puts cold plates with coolant channels on the hottest chips and, in one 2025 study's figures, has a liquid-to-air heat transfer ratio of 50% to 80% or more. Immersion cooling submerges whole servers in dielectric fluid that absorbs all of their heat.[7][9]
Does liquid cooling use less water?
In the Microsoft and WSP life-cycle assessment, cold plates and immersion cooling cut blue water consumption by 31-52% and energy demand by 15-20% compared with air cooling. These are findings of one study, not industry-wide measurements.[3]
Why is two-phase immersion controversial?
Two-phase immersion supports very high tank power densities, above 500 kW, but the fluids it uses are PFAS, which have been under legislative scrutiny.[8]
Sources
· 14 claims from 6 publishers
Each numbered claim is a statement we checked against the sources listed with it. Tap a number in the text to see its sources in place.
- [1]
A 2025 Nature life-cycle study by Microsoft and WSP authors says that as Moore's law and Dennard scaling slow, better chip performance needs more power and makes more heat, which will probably push data-center thermal loads beyond what air cooling can handle. confirmedas of 2026-11-21
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 · Author affiliations (also WSP Global Incorporated, New York) (retrieved 2026-11-21)
- [2]
NVIDIA describes its GB200 NVL72 as a rack-scale, liquid-cooled design joining 36 Grace CPUs and 72 Blackwell GPUs, and its GB300 NVL72 as a fully liquid-cooled rack-scale platform. confirmedas of 2026-11-21
- NVIDIA GB200 NVL72 · NVIDIA · Primary source (retrieved 2026-11-21)
- NVIDIA GB200 NVL72 · NVIDIA · Primary source (retrieved 2026-11-21)
- [3]
The Microsoft and WSP life-cycle assessment found that cold plates and immersion cooling cut data-center greenhouse gas emissions by 15-21%, energy demand by 15-20% and blue water consumption by 31-52% compared with air cooling; its authors describe it as, to their knowledge, the first public assessment of this kind by a hyperscale cloud provider. confirmedas of 2026-11-21
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- [4]
The same study says exceeding thermal limits can reduce clock frequency and degrade component performance, and that excess heat reduces how densely servers can be packed. confirmedas of 2026-11-21
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- [5]
In May 2023 the US Department of Energy said cooling can account for up to 40% of a data center's energy use, and announced $40 million for 15 projects under ARPA-E's COOLERCHIPS program to develop more efficient data-center cooling. confirmedas of 2026-11-21
- DOE Announces $40 Million for More Efficient Cooling for Data Centers · U.S. Department of Energy · Primary source · 2023-05-09 (retrieved 2026-11-21)
- DOE Announces $40 Million for More Efficient Cooling for Data Centers · U.S. Department of Energy · Primary source · 2023-05-09 (retrieved 2026-11-21)
- [7]
Cold plates, also called direct-to-chip cooling, are small heat-exchange modules with microchannels placed on top of high-power chips; a coolant loop carries the chip's heat out of the server, and the study gives a cold-plate system's liquid-to-air heat transfer ratio as 50% to 80% or more. confirmedas of 2026-11-21
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- [8]
According to the study, cold plates can be added to existing air-cooled data centers with less disruption but may still need air cooling; one-phase immersion uses cheaper coolants and simpler tanks than two-phase; two-phase immersion supports tank power densities above 500 kW but uses PFAS fluids that face legislative scrutiny. confirmedas of 2026-11-21
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- [9]
Immersion cooling submerges whole servers in tanks of dielectric fluid that absorb all of the heat they generate, which makes server fans unnecessary. confirmedas of 2026-11-21
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- [10]
The Open Compute Project's Cooling Environments project works on five areas of advanced data-center cooling - cold plates, coolant distribution units, immersion, door heat exchangers and heat reuse - and notes that high-performance computing has long used liquid cooling. confirmedas of 2026-11-21
- Cooling Environments project · Open Compute Project Foundation · Primary source (retrieved 2026-11-21)
- Cooling Environments project · Open Compute Project Foundation · Primary source (retrieved 2026-11-21)
- [11]
NVIDIA says liquid cooling increases compute density and reduces the floor space used. reportedas of 2026-11-21
- NVIDIA GB200 NVL72 · NVIDIA · Primary source (retrieved 2026-11-21)
- [12]
One-phase immersion moves heat by convection into a fluid, usually hydrocarbon-based, that is pumped through the servers; two-phase immersion uses a fluid that boils at 30 to 50 °C, rises as vapour to a condenser coil and condenses back to liquid. confirmedas of 2026-11-21
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- Using life cycle assessment to drive innovation for sustainable cool clouds (Nature 641, 331-338) · Nature (via PubMed Central) · Primary source · 2025-04-30 (retrieved 2026-11-21)
- [13]
One COOLERCHIPS award went to Intel Federal to adapt a two-phase immersion cooling system. confirmedas of 2026-11-21
- DOE Announces $40 Million for More Efficient Cooling for Data Centers · U.S. Department of Energy · Primary source · 2023-05-09 (retrieved 2026-11-21)
- [14]
The JUPITER Booster is warm-water cooled using Eviden's BullSequana XH3000 design, and Forschungszentrum Jülich plans to reuse its waste heat in the Jülich campus heating network. confirmedas of 2026-11-21
- A Deep Dive Into JUPITER's Building Blocks · Forschungszentrum Jülich (Jülich Supercomputing Centre) · Primary source (retrieved 2026-11-21)
- Grand ceremony marks the launch of the Exascale Supercomputer JUPITER · Forschungszentrum Jülich · Primary source · 2025-09-05 (retrieved 2026-11-21)
Revision history (1)
- Page created.
Created Nov 21, 2026. Last reviewed by an editor on Nov 22, 2026. Next scheduled review: May 18, 2027.
Cite this page
"Liquid cooling in AI data centers explained." ContentLora, updated Nov 22, 2026. https://contentlora.com/explain/data-center-liquid-cooling-explained
Spotted an error? Suggest a correction or emailcorrections@contentlora.com.